•   +98 21 26 910 778      |      
  •   o g s @ i r x p . c o m

 

×

Error message

  • Warning: Trying to access array offset on false in comment_page_title_pattern_alter() (line 40 of /var/www/vhosts/buy-bitumen.com/httpdocs/sites/all/modules/page_title/modules/comment.page_title.inc).
  • Deprecated function: strncmp(): Passing null to parameter #1 ($string1) of type string is deprecated in comment_page_title_pattern_alter() (line 40 of /var/www/vhosts/buy-bitumen.com/httpdocs/sites/all/modules/page_title/modules/comment.page_title.inc).
  • Warning: Trying to access array offset on false in node_page_title_pattern_alter() (line 33 of /var/www/vhosts/buy-bitumen.com/httpdocs/sites/all/modules/page_title/modules/node.page_title.inc).
  • Deprecated function: strncmp(): Passing null to parameter #1 ($string1) of type string is deprecated in node_page_title_pattern_alter() (line 33 of /var/www/vhosts/buy-bitumen.com/httpdocs/sites/all/modules/page_title/modules/node.page_title.inc).
  • Warning: Trying to access array offset on false in taxonomy_page_title_pattern_alter() (line 31 of /var/www/vhosts/buy-bitumen.com/httpdocs/sites/all/modules/page_title/modules/taxonomy.page_title.inc).
  • Deprecated function: strncmp(): Passing null to parameter #1 ($string1) of type string is deprecated in taxonomy_page_title_pattern_alter() (line 31 of /var/www/vhosts/buy-bitumen.com/httpdocs/sites/all/modules/page_title/modules/taxonomy.page_title.inc).
  • Warning: Trying to access array offset on false in views_page_title_pattern_alter() (line 15 of /var/www/vhosts/buy-bitumen.com/httpdocs/sites/all/modules/page_title/modules/views.page_title.inc).
Iran Bitumen Grade 60/70
Bitumen 60/70 for Export
     
Bitumen 60/70 is the most popular bitumen grade for road construction and other industrial purposes. Below is the product's specification table which will be documented and certified by SGS or any third party inspection company the client wishes:

BLOWN BITUMEN 60/70

Specification

Test Method

Specific gravity   @ 25/25° C

1.01~1.06

D~70

Penetration   @ 25° C

60/70

D~5

Softening point ° C

49/56

D~36

Ductility   @ 25° C

100 min

D~113

Loss on Heating   (wt) %

0.2 max

D~6

Drop in Penetration after Heating %

20 max

D~6 & D~5

Flash point ° C

250 min

D~92

Solubility in Cs2   (wt) %

99.5 min

D~4

Spot Test

Negative

٭A.A.S.H.O.T.102

٭American Association of state Highway Officials.

 